More from this brand
The Sevcon Gen4 range supports configuration, calibration, control and status monitoring over a CAN bus using the industry-standard CANopen protocol. In order to support a wide range of applications, the unit is able to be configured as either an NMT master or slave device.
Gen4 controllers can be configured to support limited compatibility with a J1939 bus.
To take full advantage of the features of CAN communication on a Sevcon product, an IXXAT CAN to USB device with Sevcon DVT Software subscription will be required.
Ingress Protection:
The Sevcon Gen4 range is IP66 rated, providing total protection against dust ingress and protection against water ingress during high powered pressure washing.
Motor Support:
The Gen4 range provides support for the following motor types and control modes:
- PMAC
Encoder Support:
The Gen4 range provides support for the following sensor types:
- A
- AB
- UVW
- ABUVW
- Sin/Cos (Specific hardware only)
- Resolver (Size 8 and 10 models only)
Connectivity:
Power connections are made through M8 terminal posts. This includes the DC link from a battery or other source via a fuse (mounted on-board) and 3-phase output to the motor.
Signal connections are made through a 35-Way Ampseal connector. Signal connections include:
- 1x Encoder connection (power supply and signal connections)
- 2x CAN bus connection (internally linked. Termination available)
- 8x Configurable digital inputs
- 4x Configurable analogue inputs
- 3x Configurable contactor driver outputs
- 1x Thermistor input
- 5V and 10V power supply outputs (Specific hardware only)
Documents:
| Dimensions | |
| Dimensions | 227mm x 168mm x 78mm |
| Weight | 2.7kg |
| IP Rating | |
| IP Rating | IP66 |
| Motor Controller | |
| Minimum Supply Voltage (V) | 39.1 |
| Nominal Supply Voltage (V) | 80 |
| Maximum Supply Voltage (V) | 116 |
| Peak Current (A) | 350 |
| Boost Current (A) | 420 |
| Continuous Current (A) | 140 |